Highlights

Triple-enzyme blend. protease breaks down blood and protein soil, lipase targets fats, and amylase clears starch residue — covering the three dominant organic soil types found on surgical and lab instruments.

Pre-soak & ultrasonic compatible. formulated for manual pre-soak basins as well as ultrasonic cleaning baths ahead of autoclave sterilisation.

Low-foam formula. suitable for ultrasonic and mechanical washer-disinfector use where excess foam would interfere with cavitation and cleaning action.

Material-safe. non-corrosive to stainless steel, aluminium, and common instrument finishes at recommended dilution and soak time.

Neutral pH. reduces the risk of instrument surface damage versus alkaline pre-soak alternatives over repeated processing cycles.

The chemistry

Why does instrument reprocessing rely on enzymes rather than a standard detergent, and why combine three different enzyme types? Surgical soil is a mixture of blood proteins, tissue fats, and occasionally starch-based lubricants or residues, each of which requires a different breakdown mechanism.

Protease enzymes cleave peptide bonds in blood and tissue proteins, breaking large coagulated protein structures into smaller, water-soluble fragments that rinse away rather than baking onto the instrument surface during subsequent heat exposure. Lipase enzymes hydrolyse fat and lipid soil into fatty acids and glycerol, addressing residue that protease alone cannot break down. Amylase targets starch-based residues, completing coverage across the organic soil types typically encountered.

Because enzymatic breakdown of protein soil is essential before autoclave sterilisation — heat-fixed protein residue can shield underlying microorganisms from steam penetration — an effective pre-soak is a genuine safety step in the sterilisation chain, not just a cleaning convenience.

Application & usage

Pre-soak. Dilute 5–10 ml per litre of lukewarm water (not hot — heat can denature enzymes). Fully immerse instruments for 5–10 minutes.

Ultrasonic bath. Use the same dilution in the ultrasonic tank per equipment manufacturer’s cycle time guidance, then rinse thoroughly before autoclaving.

Product specifications

Active system

Protease + lipase + amylase enzyme blend

pH

6.5–7.5 (neutral)

Formulation type

Low-foam liquid concentrate

Fragrance

None

Dilution

5–10 ml per litre (1:100 to 1:200)

Application

Manual pre-soak basin / ultrasonic bath

Rinse after use

Yes — thorough rinse required before sterilisation

PPE

Gloves recommended when handling soiled instruments

Shelf life

18 months from date of manufacture, unopened

Pack size

5 Litres / Bulk on request

MSDS / TDS

QR code on label · Available on request

Caution & storage
🚨 For professional and institutional use only

  • Handle soiled instruments per your facility’s bio-hazard handling protocol; treat all pre-soak solution as contaminated waste.
  • Avoid contact with eyes. May cause mild irritation in individuals sensitised to enzyme proteins.
  • In case of eye contact, rinse immediately with clean water.
  • Do not use water above 45°C — excess heat deactivates the enzyme system.
  • Keep out of reach of children.
  • Store in original sealed container below 25°C, away from direct sunlight.
  • Shelf life 18 months from manufacture date, unopened.
Resources & documentation

Material Safety Data Sheets (MSDS) and Technical Data Sheets (TDS) are available on request and accessible via the QR code printed on the product label.

MSDS / TDS requests: care@allesclinx.com

Bulk & institutional supply enquiries: procurement@allesclinx.com